1756-TBCH Allen-Bradley ControlLogix 36-Pin Cage Clamp RTBProduct Overview The Allen Bradley 1756 TBCH is a 36 position Removable Terminal Block (RTB) designed specifically for high density ControlLogix I O modules. It provides the critical interface between field wiring and the PLC hardware, allowing for seamless connection of sensors, actuators, and power sources. We supply this unit as 100% Brand New and Original in factory packaging. This component is essential for any 1756 series module requiring a 36
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Allen-Bradley 1756-TBCH is a 36-position Removable Terminal Block (RTB) designed specifically for high-density ControlLogix I/O modules. It provides the critical interface between field wiring and the PLC hardware, allowing for seamless connection of sensors, actuators, and power sources. We supply this unit as 100% Brand New and Original in factory packaging. This component is essential for any 1756-series module requiring a 36-pin connection, ensuring a gas-tight, vibration-resistant termination for industrial environments.

Technical Specifications

Specification Technical Details
Connection Type Cage Clamp (Screw-actuated)
Number of Positions 36 Terminals
Wire Size Range 22–14 AWG (Solid or Stranded)
Screwdriver Width 3.2 mm (1/8 in.)
Screw Torque 0.5 Nm (4.4 lb-in) to 0.6 Nm (5 lb-in)
Isolation Voltage 250V Continuous (Basic Insulation)
Housing Style Low-Profile / Standard
Mounting Front-mount on 1756 I/O Modules
Operating Temperature 0 to 60 °C (32 to 140 °F)
Product Net Weight 0.14 kg (0.31 lbs)
Shipping Weight 2.00 kg (Securely packed for logistics)

Engineering Advantages

  • Zero-Downtime Maintenance: The 1756-TBCH allows users to replace I/O modules without disconnecting a single field wire. Technicians simply unlock the RTB, swap the module, and re-seat the block, reducing Mean Time to Repair (MTTR) from hours to minutes.

  • Mechanical Keying Protection: This terminal block supports mechanical keying to prevent accidental insertion into the wrong type of I/O module. This safeguard eliminates the risk of applying high-voltage signals to low-voltage logic circuits during maintenance.

  • Superior Connection Stability: The cage clamp design applies constant pressure to the wire, which compensates for thermal expansion and mechanical vibration. Unlike standard screw terminals that may loosen over time, the 1756-TBCH maintains a low-resistance path in high-vibration machinery applications.

  • High-Density Wiring Management: The low-profile housing organizes 36 distinct wires within a 35mm width. This density enables high-point-count I/O configurations while maintaining a clean, professional appearance inside the control panel.

FAQs

What is the difference between the 1756-TBCH and the 1756-TBS6H?

The 1756-TBCH uses a Cage Clamp (screw-actuated clamp) which requires a screwdriver to tighten the wire. The 1756-TBS6H uses a Spring Clamp (push-in style). Both feature 36 pins and fit the same modules, but the TBCH is preferred for applications where specific torque settings must be documented for compliance.

Which Allen-Bradley modules require the 1756-TBCH?

This RTB is required for high-density digital and analog modules, such as the 1756-IB32, 1756-OB32, and certain 1756-series analog modules. Standard 16-point modules typically use the 20-pin 1756-TBNH instead. Always check your I/O module's user manual to confirm pin count.

Can I reuse a 1756-TBCH when upgrading my PLC?

Yes, as long as the terminal block is in good physical condition and the new module supports 36-pin RTBs. However, we recommend inspecting the clamps for fatigue or oxidation. Given the critical role of the RTB, many engineers install a Brand New 1756-TBCH during system overhauls to ensure maximum connection reliability.

Does the 1756-TBCH include the housing?

Yes, this part number includes the 36-pin terminal block and the standard low-profile housing that protects the wiring and provides the locking latch for the I/O module.

1756-TBCH Allen-Bradley ControlLogix 36-Pin Cage Clamp RTB

Item no : 79856174539
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches