Siemens Original HydroRanger 200 HMI Level MeasurementOverview MultiRanger HydroRanger 200 HMI is a versatile short to medium range ultrasonic single and multi vessel level monitor controller for virtually any application in a wide range of industries. HydroRanger 200 HMI is an ultrasonic level controller for up to six pumps and provides control, differential control, and open channel flow monitoring. Benefits Easy to use HMI display with local four button programming, menu driven parameters, and Wizard
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Overview

MultiRanger/HydroRanger 200 HMI is a versatile short- to medium-range ultrasonic single- and multi-vessel level monitor/controller for virtually any application in a wide range of industries.HydroRanger 200 HMI is an ultrasonic level controller for up to six pumps and provides control, differential control, and open channel flow monitoring.

Benefits

- Easy to use HMI display with local four-button programming, menu-driven parameters, and Wizard support for key applications
- English, German, French, Spanish, Chinese, Italian, Portuguese, and Russian texts on the HMI
- Removable terminal blocks for ease of wiring
- Monitors wet wells, weirs, and flumes
- Communication using built-in Modbus RTU via RS 485 and SIMAT IC PDM
configuration software
- Compatible with SmartLinx system: PROFIBUS DP, PROFINET (cyc lic access of process values only),
DeviceNet, Modbus TCP/IP, and EtherNet/IP
- Single or dual point level monitoring
- 6 relays
- Auto False-Echo Suppression for fixed obstruction avoidance
- Anti-grease ring/tide mark buildup
- Differential amplifier transceiver for common mode noise rejec tion and improved signal-to-noise ratio •Wall and panel mounting options
 

Application


For water authorities, municipal water, and wastewater plants, HydroRanger 200 HMI is an economical, low-maintenance
solution delivering control efficiency and productivity needed to meet today’s exacting standards. It offers single point
monitoring with all models, and optional dual-point monitoring with 6 relay model. As well, it has digital communications with built-in Modbus RTU via RS 485. The standard 6 relay HydroRanger 200 HMI will monitor open chan nel flow and features advanced relay alarming and pump control functions as well as volume conversion. It is compatible with SIMAT IC PDM, allowing for PC configuration and set-up. Sonic Intelligence advanced echo-processing software provides increased reading reli ability.

HydroRanger 200 HMI uses proven continuous ultrasonic echo ran ging technology to monitor water and wastewater of any consist ency up to 15 m (50 ft) in depth. Achievable resolution is 0.1 % with accuracy to 0.25 % of range. Unlike contacting devices, HydroRanger 200 HMI is immune to problems caused by suspended solids, harsh corrosives, grease or silt in the effluent, reducing downtime
•Key Applications: wet wells, flumes/weirs, bar screen controlSpecification

Specification

Measuring principle

Ultrasonic level measurement

Measuring range

0.3 ... 15 m (1 ... 50 ft), transducer dependent

Accuracy

Error in measurement- 0.25 % of range or 6 mm (0.24 inch), whichever is greater - ± 4 mm (0.16 inch) in combination with an XRS-5 transducer on ranges

4 m (13 ft) or less

Ambient temperature (enclosure)

-20 ... +50 °C (-4 ... +122 °F)

Material (enclosure)

Polycarbonate

Power supply

100 ... 230 V AC ± 15 %, 50/60 Hz, 36 VA (17 W)

Displays and controls

60 x 40 mm (2.36 x 1.57 inch) LCD 240 x 160 pixels resolution

Certificates and approvals

- CE, UKCA, RCM, EAC, KC4) •FM, CCSAUS, UL listed - CCSAUS Class I, Div. 2, Groups A, B, C, D, Class II, Div. 2, Groups F, G, ClassIII (wall mount only) - MCERTS Class 2 approved for Open Channel Flow

Communication

- RS 232 with Modbus RTU or ASCII via RJ-11 connector - RS 485 with Modbus RTU or ASCII via ter minal blocks - Optional: SmartLinx cards for-PROFIBUS DPV1, PROFINET (cyclic access of process values only)-DeviceNet, Modbus TCP/IP, EtherNet/IP

Siemens Original HydroRanger 200 HMI Level Measurement

Item no : 25606817686
sold recently : Login >>
US$ 406.25
Pay in 4 interest-free payments of $101.56 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 23 - Jun 28

Enjoy 20% off shipping

US$ 406.25

1-11

US$ 365.62

12-35

US$ 284.38

36-59

US$ 243.75

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches