Buy New 1756-IR6I Allen Bradley ControlLogix RTD Input CardProduct Overview The Allen Bradley 1756 IR6I functions as a high precision temperature measuring module for the ControlLogix platform. It provides six individually isolated channels designed specifically for Resistance Temperature Detectors (RTD) and direct resistance signals. By isolating each channel from the others and the backplane, this module eliminates ground loops and maintains signal integrity in electrically noisy industrial environments. We
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Allen Bradley 1756-IR6I functions as a high-precision temperature-measuring module for the ControlLogix platform. It provides six individually isolated channels designed specifically for Resistance Temperature Detectors (RTD) and direct resistance signals. By isolating each channel from the others and the backplane, this module eliminates ground loops and maintains signal integrity in electrically noisy industrial environments. We deliver this module as 100% Brand New original stock to ensure the highest accuracy for your thermal process monitoring.

Technical Specifications

Feature Specification
Number of Inputs 6 Individually Isolated RTD/Resistance
Supported RTD Types Pt100, Pt200, Pt500, Pt1000, Ni120, Ni1000, Cu10, Cu50
Resistance Range 0 to 3000 Ω
Resolution 16-bit
Accuracy ±0.1% of Full Scale (Typical)
Isolation Voltage 250V (Continuous) Channel-to-Channel & Channel-to-System
Conversion Method Sigma-Delta
Data Format IEEE 32-bit Floating Point or Integer Mode
Noise Rejection 60 dB at 60 Hz
Overvoltage Protection 24V AC/DC (Max)

Engineering Advantages

  • Individual Channel Isolation: The 1756-IR6I features 250V continuous isolation between every channel. This architecture prevents common-mode noise and ground loops from affecting adjacent readings, which is critical when sensors are located far from the PLC chassis across different ground potentials.

  • High-Resolution Sigma-Delta Conversion: The module utilizes Sigma-Delta conversion technology to filter out high-frequency noise and provide stable, 16-bit resolution. This ensures precise temperature data for applications requiring tight PID control loops.

  • Broad Resistance Compatibility: Beyond standard Platinum RTDs, the module measures general resistance up to 3000 Ohms. This allows engineers to interface specialized sensors or potentiometers without requiring dedicated conversion hardware.

  • Advanced Diagnostics: The 1756-IR6I continuously monitors each channel for "Open Wire" or "Short Circuit" conditions. The module flags these faults in the controller software, allowing for rapid identification of cable damage or sensor failure without physical probing.

FAQs

What is the benefit of the "I" suffix in 1756-IR6I compared to standard modules?

The "I" stands for Individually Isolated. While standard modules may group inputs together, the 1756-IR6I isolates every channel. This setup allows you to connect RTDs from different power zones or equipment without worrying about cross-channel interference or damage from potential differences.

Can I mix different RTD types on a single module?

Yes. You can configure each of the six channels independently within the Studio 5000 software. For example, you can monitor a Pt100 sensor on channel 0 and a Ni120 sensor on channel 1 simultaneously.

Does this module require a specific Removable Terminal Block (RTB)?

Yes, for 1756 Analog modules, we recommend using the 1756-TBNH (20-pin Cage Clamp) or 1756-TBSH (20-pin Spring Clamp). Ensure you use shielded twisted-pair cable to maintain the accuracy specifications listed.

Can the 1756-IR6I measure thermocouples?

No. This module is strictly for RTD and resistance-based measurements. If your application requires thermocouple inputs, you should select the 1756-IT6I or 1756-IRT8I modules instead.

Buy New 1756-IR6I Allen Bradley ControlLogix RTD Input Card

Item no : 1334135663
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches