20% OFF shipping at africanheritageservices.org on orders over $79 + up to 10% OFF products
africanheritageservices.org
home > Allen-Bradley 1762-OW8 | 8 Point Normally Open Relay Module > Allen-Bradley 1762-OW8 | 8 Point Normally Open Relay Module
download picture
Allen-Bradley 1762-OW8 | 8 Point Normally Open Relay ModuleProduct Overview The Allen Bradley 1762 OW8 is a high performance expansion relay output module designed for the MicroLogix 1100, 1200, and 1500 controller families. It provides eight physically isolated, normally open (N. O.) relay contacts that interface the PLC logic with high power field devices such as motor starters, solenoids, and indicators. By utilizing electromechanical relays, this module allows for flexible switching of both AC and DC
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Product Overview

The Allen-Bradley 1762-OW8 is a high-performance expansion relay output module designed for the MicroLogix 1100, 1200, and 1500 controller families. It provides eight physically isolated, normally open (N.O.) relay contacts that interface the PLC logic with high-power field devices such as motor starters, solenoids, and indicators. By utilizing electromechanical relays, this module allows for flexible switching of both AC and DC loads within a wide voltage range. We provide this unit as 100% Brand New and Original in factory packaging, ensuring reliable operation for your critical automated sequences.

Technical Specifications

Specification Technical Details
Number of Outputs 8 Normally Open (N.O.) Contacts
Operating Voltage (AC) 5 to 265V AC
Operating Voltage (DC) 5 to 125V DC
Continuous Current per Point 2.5 A (Maximum)
Continuous Current per Module 8 A (Maximum)
Contact Configuration Form A (SPST-NO)
Terminal Type Finger-safe Screw Clamp Terminals
Mounting Style DIN Rail or Panel Mount
Operating Temperature 0 to 55 °C (32 to 131 °F)
Product Net Weight 0.14 kg (0.30 lbs)
Shipping Weight 1.00 kg (Includes protective logistics packaging)

Engineering Advantages

  • Universal Load Compatibility: The 1762-OW8 switches both AC and DC voltages across its relay contacts. This versatility eliminates the need for separate digital output modules when managing mixed-voltage loads like 120V AC contactors and 24V DC pilot lights.

  • Galvanic Isolation: The module provides robust electrical isolation between the field-side wiring and the PLC backplane. This protects the MicroLogix processor from high-voltage surges and electromagnetic interference (EMI) generated by inductive load switching.

  • High Current Capacity: Each individual relay point handles up to 2.5 Amps. This high current rating allows the module to drive many small motors and industrial solenoids directly, bypassing the cost and space required for intermediate interposing relays.

  • Seamless MicroLogix Integration: Designed for the 1762 expansion bus, the module snaps directly onto the right side of your MicroLogix controller or adjacent expansion modules. This compact "bus-connection" design requires no additional power wiring for module communication.

FAQs

Can the 1762-OW8 be used with a MicroLogix 1500 system?

Yes. While the MicroLogix 1500 primarily uses 1764-series base units and processors, it utilizes 1762-series expansion modules for its I/O growth. The 1762-OW8 is the standard 8-point relay expansion choice for MicroLogix 1100, 1200, and 1500 systems.

Does this module require an external 24V DC power supply?

The module draws its logic power directly from the controller via the 1762 expansion bus. However, you must provide the external load voltage (e.g., 120V AC or 24V DC) to the relay common terminals (VAC/VDC) to power your field devices.

What is the life expectancy of the internal relays?

The electromechanical relays typically provide approximately 10 million cycles under no-load conditions. Under full rated load, the life expectancy varies based on the inrush current. To extend relay life, we strongly recommend using external surge suppressors (RC networks for AC or flyback diodes for DC) when switching inductive loads like solenoids.

Is it possible to mix AC and DC voltages on the same module?

Yes, but you must be careful with common terminals. The 1762-OW8 groups outputs into shared common blocks. You can switch different voltages across different common groups, but all outputs sharing a single common terminal must use the same voltage source.

Allen-Bradley 1762-OW8 | 8 Point Normally Open Relay Module

Item no : 1234159723
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches